 Multi-rate OC-48/STM-16 LR-2/L-16.2 SFP CWDM Transceivers with Digital Diagnostics
TRPA48L2M CWDM
Product Description
The TRPA48L2M CWDM SFP series of multi-rate fiber optic transceivers with digital diagnostics monitoring functionality provide a quick and reliable interface for long reach (LR-2) applications. Diagnostics monitoring functionality (alarm and warning features) is integrated into the design via an I2C serial interface per the Multi-Source Agreement (MSA) SFF-8472, Rev. 9.4. Products under this series are compatible with SONET/SDH standards for OC-48/STM-16 (2.488Gb/s) LR-2/L-16.2 long reach applications, OC-3/STM-1 (156Mb/s) and OC-12/STM-4 (622Mb/s) SR/I-1 and I-4 short reach applications; Gigabit Ethernet LX (1.25Gb/s) applications per IEEE 802.3; and Fibre Channel 200-SM-LC-L (2.125Gb/s) and 100-SM-LC-L (1.062Gb/s) applications per FC-PI standards. The transceivers support data rates ranging from 2.67Gb/s down to 125Mb/s and are available in eight (8) wavelengths: 1471nm, 1491nm, 1511nm, 1531nm, 1551nm, 1571nm, 1591nm and 1611nm. The higher optical link power budget of 28dB is to accommodate the wavelength multiplexing and de-multiplexing insertion losses. All transceivers are Class I Laser products per U.S. FDA/CDRH and international IEC-60825 standards. The TRPA48L2M CWDM transceivers connect to standard 20-pad SFP connectors for hot plug capability. This allows the system designer to make configuration changes or maintenance by simply plugging in different types of transceivers without removing the power supply from the host system. The transceivers have colored bail-type latches, which offer an easy and convenient way to release the modules. The latch is compliant with the SFP MSA. The transmitter and receiver DATA interfaces are AC-coupled internally. LV-TTL Transmitter Disable control input and Loss of Signal (LOS) output interfaces are also provided. The transceivers operate from a single +3.3V power supply over an operating case temperature range of -5C to +70C ("B" option) or -5C to +85C ("E" option). The housing is made of metal for EMI immunity.
Features
Eight (8) Wavelength CWDM Transceivers Compatible with SFP MSA Compatible with SONET/SDH OC-48/STM-16 (2.488Gb/s) LR-2/L-16.2 Applications Compatible with Gigabit Ethernet LX Compatible with Fibre Channel 200-SM-LC-L and 100-SM-LC-L Digital Diagnostics through Serial Interface Internal Calibration for Digital Diagnostics APD Receiver Optical Link Power Budget of 28dB Minimum Eye Safe (Class I Laser Safety) Hot-pluggable TX Fault & Loss of Signal Outputs TX Disable Input
Absolute Maximum Ratings
Parameter Storage Temperature Operating Case Temperature1 Supply Voltage Maximum Input Optical Power (30 seconds max.) Input Voltage
1
Symbol TST "B" Option "E" Option TOP VCC Pin,max VIN
Minimum - 40 -5 -5 0 0
Maximum + 85 + 70 + 85 + 4.5 + 3.0 VCC
Units C C V dBm V
Measured on top side of SFP module at the front center vent hole of the cage.
An Oplink Company
RevB-NP.2008.09.09
TRPA48L2M CWDM
Transmitter Performance Characteristics
All parameters guaranteed only at typical data rate Parameter Operating Data Rate Average Optical Output Power (coupled into single mode fiber), 50% duty cycle Extinction Ratio 1471 1491 1511 Center Wavelength 1531 1551 1571 1591 1611 Spectral Width (-20dB) Side Mode Suppression Ratio Optical Rise/Fall Time (20% to 80%) Relative Intensity Noise Jitter Generation Dispersion Penalty
2
(Over Operating Case Temperature. VCC = 3.13 to 3.47V) Minimum 0.125 0 8.2 1464.5 1484.5 1504.5 1524.5 1544.5 1564.5 1584.5 1604.5 Typical 1471 1491 1511 1531 1551 1571 1591 1611 Maximum 2.67 + 5.0 1477.5 1497.5 1517.5 1537.5 1557.5 1577.5 1597.5 1617.5 1.0 0.16 - 117 0.07 2.0 nm dB ns dB/Hz UIp-p dB nm Units Mb/s dBm dB
Symbol B PO Phi /Plo
C
20 SMSR t r , tf RIN OC-48 JG -
30 ---
2
Optical Output Eye
Compliant with Telcordia GR-253-CORE and ITU-T Recommendation G.957
Specified at 1760ps/nm dispersion, which corresponds to the approximate worst-case dispersion for 80km G.652/G.654 fiber over the center wavelength range of 1464.5-1617.5nm.
Receiver Performance Characteristics
All parameters guaranteed only at typical data rate Parameter Operating Data Rate Receiver Sensitivity (10-10 BER)1 Receiver Sensitivity (10-12 BER)2 OC-3/12/48, 2.67Gb/s 2.125Gb/s, 1.25Gb/s, 1.062Gb/s, 0.125Gb/s Increasing Light Input Decreasing Light Input Increasing Light Input Decreasing Light Input
(Over Operating Case Temperature. VCC = 3.13 to 3.47V) Minimum 0.125 - 28.0 - 28.0 - 8.0 - 42.0 2.3 0.53 1260 Typical Maximum 2.67 - 28.0 100 100 1620 - 27.0 Units Gb/s dBm dBm dBm dBm s dB nm dB
Symbol B Pmin Pmin Pmax Plos+ Plost_loss_off t_loss_on -
Maximum Input Optical Power (10 -12 BER) LOS Thresholds LOS Timing Delay LOS Hysteresis Wavelength of Operation Receiver Reflectance
1 2 3
Measured with 223-1 PRBS. Measured with 27-1 PRBS. For OC-3, Minimum Hysteresis is 0.2dB.
Oplink Communications, Inc.
2
RevB-NP.2008.09.09
TRPA48L2M CWDM
Transmitter Performance Characteristics
Parameter Input Voltage Swing (TD+ & TD-) 1 Input HIGH Voltage (TX Disable) Input LOW Voltage (TX Disable) Output LOW Voltage (TX Fault)
1 2 3
(Over Operating Case Temperature. VCC = 3.13 to 3.47V) Minimum 0.35 2.0 0 2.0 0 Typical Maximum 1.75 VCC 0.8 VCC + 0.3 0.8 Units V V V V V
Symbol VPP-DIF VIH VIL VOH VOL
2
2
Output HIGH Voltage (TX Fault) 3
3
Differential peak-to-peak voltage. There is an internal 4.7 to 10k pull-up resistor to VccT. Open collector compatible, 4.7 to 10k pull-up resistor to Vcc (Host Supply Voltage).
Receiver Electrical Interface
Parameter Output Voltage Swing (RD+ & RD-) Output HIGH Voltage (LOS) Output LOW Voltage (LOS))
1 2
(Over Operating Case Temperature. VCC = 3.13 to 3.47V)) Symbol Minimum 0.40 VCC - 1.3 0 Typical Maximum 1.75 VCC + 0.3 0.5 Units V V V
1
VPP-DIF VOH VOL
2 2
Differential peak-to-peak voltage across external 100 load. Open collector compatible, 4.7 to 10k pull-up resistor to Vcc (Host Supply Voltage).
Electrical Power Supply Characteristics
Parameter Supply Voltage Supply Current VCC ICC
(Over Operating Case Temperature. VCC = 3.13 to 3.47V)) Minimum 3.13 Typical 3.3 210 Maximum 3.47 350 Units V mA
Symbol
Module Definition
MOD_DEF(0) pin 6 MOD_DEF(1) pin 5 MOD_DEF(2) pin 4 Interpretation by Host
TTL LOW
SCL
SDA
Serial module definition protocol
Electrical Pad Layout
20 19 18 17 16 15 14 13 12 11
TX GND TD- (TX DATA IN-) TD+ (TX DATA IN+) TX GND VccTX VccRX RX GND RD+ (RX DATA OUT+) RD- (RX DATA OUT-) RX GND
Host Board Connector Pad Layout
20 19 18 17 16 15 14 13 12 11
Toward ASIC
1 2 3 4 5 6 7 8 9 10
TX GND TX Fault TX Disable MOD_DEF(2) MOD_DEF(1) MOD_DEF(0) NO CONNECTION LOS RX GND RX GND
1 2 3
Toward Bezel
4 5 6 7 8 9 10
Top of Board
Bottom of Board (as viewed thru top of board)
Oplink Communications, Inc.
3
RevB-NP.2008.09.09
TRPA48L2M CWDM
Example of SFP host board schematic
Vcc 3.3V
1H coil or ferrite bead (<0.2 series resistance) Vcc 3.3V
+
10
0.1
0.1
16 15
RR
2 8 4 6
R
R
TX Fault LOS MOD_DEF(2) MOD_DEF(1) MOD_DEF(0)
(100 to ground internally)
+
10
0.1
TX Disable TX DATA IN+ TX DATA IN-
3
TRPA48L2M 5 CWDM
100 13 12
18 19
RX DATA OUT+ to 50 load RX DATA OUTto 50 load
1, 9, 10, 11, 14, 17, 20
R: 4.7 to 10k Application Notes
Electrical interface: All signal interfaces are compliant with the SFP MSA specification. The high speed DATA interface is differential AC-coupled internally with 0.1F and can be directly connected to a 3.3V SERDES IC. All low speed control and sense output signals are open collector TTL compatible and should be pulled up with a 4.7 - 10k resistor on the host board Loss of Signal (LOS): The Loss of Signal circuit monitors the level of the incoming optical signal and generates a logic HIGH when an insufficient photocurrent is produced. TX_Fault: The output indicates LOW when the transmitter is operating normally, and HIGH with a laser fault including laser end-of-life. TX Fault is an open collector/drain output that should be pulled up with a 4.7 - 10k resistor on the host board. TX Fault is latched per SFP MSA. TX_Disable: When the TX Disable pin is at logic HIGH, the transmitter optical output is disabled (less than -45dBm). Serial Identification and Monitoring: The module definition of SFP is indicated by the three module definition pins, MOD_DEF(0), MOD_DEF(1) and MOD_DEF(2).
Laser Safety Laser Safety: All transceivers are Class I Laser products per FDA/CDRH and IEC-60825 standards. They must be operated under specified operating conditions.
Upon power up, MOD_DEF(1:2) appear as NC (no connection), and MOD_DEF(0) is TTL LOW. When the host system detects this condition, it activates the serial protocol (standard two-wire I2C serial interface) and generates the serial clock signal (SCL). The positive edge clocks data into the EEPROM segments of the SFP that are not write protected, and the negative edge clocks data from the SFP. The serial data signal (SDA) is for serial data transfer. The host uses SDA in conjunction with SCL to mark the startand end of serial protocol activation. The supported monitoring functions are internal temperature, supply voltage, bias current, transmitter power, average receiver signal, all alarms and warnings and software monitoring of TX Fault/LOS. The device is internally calibrated. The data transfer protocol and the details of the mandatory and vendor specific data structures are defined in the SFPMSA, and SFF-8472, Rev. 9.4 Power supply and grounding: The power supply line should be well-filtered. All 0.1F power supply bypass capacitors should be as close to the transceiver module as possible.
Oplink Communications, Inc.
DATE OF MANUFACTURE: This product complies with 21 CFR 1040.10 and 1040.11 Meets Class I Laser Safety Requirements
Oplink Communications, Inc.
4
RevB-NP.2008.09.09
TRPA48L2M CWDM
Mechanical Package
46335 Landing Pkwy Fremont, CA 94538 Tel: (510) 933-7200 Fax: (510) 933-7300 Email: Sales@Oplink.com * www.oplink.com
Dimensions in inches [mm] Default tolerances: .xxx = .005", .xx = .01"
Ordering Information
Oplink can provide a remarkable range of customized optical solutions. For detail, please contact Oplink's Sales and Marketing for your requirements and ordering information (510) 933-7200 or Sales@oplink.com.
Oplink Communications, Inc. reserves the right to make changes in equipment design or specifications without notice. Information supplied by Oplink Communications, Inc. is believed to be accurate and reliable. However, no responsibility is assumed by Oplink Communications, Inc. for its use nor for any infringements of third parties, which may result from its use. No license is granted by implication or otherwise under any patent right of Oplink Communications, Inc. RevB-NP.2008.09.09 (c) 2006, Oplink Communications, Inc. 5


▲Up To Search▲   

 
Price & Availability of TRPA48L2MCWDM

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X